Intrisically Safe Level and Temperature Sensor type ICPiT-1.*

Application:

Intrinsically safe level and temperature sensor type ICPiT-1.* is intended to supervise the level and temperature of devices components as:

  • hydraulic oil  HLP/HLL 46 or 68
  • diesel fuel for  diesel engines
  • oil-in-water emulsions HFA/HFAE,
  • mine water (technological)
  • water solutions

The temperature and level sensors type ICPiT-1.* meet the requirements of Directive ATEX  (2014/34/UE) of European Parliament and Council regarding rapprochement of legislation of European member states, for protective devices and systems used in areas in danger of explosion. It also meets the Polish legislation; the Ordinance of the Minister for the Development dated 06 Jun.  2016 (Dz. U. Nr 2016 poz. 817) for essential requirements for protective devices and systems used in areas in danger of explosion.

Intrinsically safe construction of sensors allows to use them in excavations in methane and non-methane mines, in spaces marked „a”, „b” or „c” of methane explosion danger and in spaces classified as A or B of coal dust explosion danger.

Intrinsically safe level and temperature sensor is available in three  sizes of the  terminal cover and mounting flange.

The version with an enlarged terminal cover is ideal for applications needing more space, eg. for installation of the end element.
Depending on the customer specifications, the sensor can be made with a protecting tube of the float set or without it.

Technical data:

Probe lenght
(other dimensions available)
120 – 2000 mm
Reed relay types bistable
monostable normally open,
monostable normally closed
Activation temperature from 30 to 110 °C
Temperature contact type normally closed
or normally open
Casing protection degree IP54
Mounting dimensions 4 bolts M8  on diameter ∅ 100 mm
Diameter of the mounting flange ∅ 125 mm or ∅ 120
Explosion-proof mark I M2 Ex ia I Mb
Max voltage Ui 60 V
Max. current Ii 2A
Max. power Pi 30 W
Internal capacity Ci negligible
Internal inductancea Li negligible

 

Table 1: Temperatures of opening and closing the contacts of sensor, contact NC

Temperature of opening the contact (°C) Temperature of closing the contact (°C)
30 ± 3 15 ± 4
40 ± 3 25 ± 6
50 ± 3 35 ± 6
60 ± 3 45 ± 6
70 ± 3 55 ± 6
80 ± 3 65 ± 6
90 ± 3 75 ± 6
100 ± 4 80 ± 7
110 ± 4 90 ± 7

 

Table 2: Temperatures of closing and opening the contacts of sensor, contact NO

Temperature of closing  the contact (°C) Temperature of opening  the contact (°C)
50 ± 6 35 ± 3
60 ± 6 45 ± 3
80 ± 6 65 ± 3
90 ± 6 75 ± 3
100 ± 7 80 ± 4

 

 

Type Code